Flowserve LPC Compact Actuator Series Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Flowserve LPC Compact Actuator Series. Flowserve LPC Compact Actuator Series User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - USER INSTRUCTIONS

USER INSTRUCTIONSInstallation Operation MaintenanceLPC Compact Actuator SeriesSingle Acting & Double ActingFCD LFENIM0002-00-AQ – 07/14Experience

Strona 2 - Contents

Figure 8: Double Acting Actuator Configuration – Open PositionFigure 9: Fail Close Configuration With Valve

Strona 3 - Standard Information

3 Field ConversionFor field conversion from fail open (CCW) to fail close (CW) and vice versa, follow the following steps.NOTE: • An additional adapte

Strona 4 - 1.7 Service/Repair

LPC series compact actuators are designed to offer the greatest ease of operations of assembly, disassembly and main-tenance. The maintenance and disa

Strona 5 - 1.8 Storage

Standard in-field maintenance Perform the following steps with reference to Figure 15:4.2.1 Unscrew and remove the travel stop of the pneumatic c

Strona 6 - 1.10 Unpacking

4.3 Housing and Scotch Yoke Maintenance Standard maintenance of the housing may take place in the field.Standard in–field maintenanceA first standard ma

Strona 7 - Installation Instructions

5 TroubleshootingTo prevent the actuator from not proper functioning or low performance, first ensure that the installation and the adjust-ment operati

Strona 8 - 2.4 Pneumatic Supply Fluids

Troubleshooting TableProblem Possible cause SolutionThe actuator does not move.A moving part is seized up.Check if any moving part is blocked. If so,

Strona 9 - 2.5 Initial Operation

6 Disposal of Decommissioned ActuatorsActuators that are to be decommissioned permanently due to a plant closure or for another reason must have th

Strona 10

7 AnnexCode Material Temperature Range Climate Classification According to IEC60721B Buna Std Temp: -29°C to +100°C (-20°F to 212°F)Tropical & Arid

Strona 11 - Field Conversion

Dimensions mm (in) - Kg (lbs)Model A B D E K H L Q Z 'N' NPT PORT WeightLPC-05X-080Y-SR01716 178 100 438 38 175 69 120 1401/4"3728.19 7

Strona 12 - Maintenance Instructions

Contents1 Standard Information 3 1.1 General Usage 3 1.2 Terms Concerning Safety 3 1.3 Protective Clothing 4 1.4 Qualified Personnel

Strona 13 - flowserve.com

Dimensions mm (in) - Kg (lbs)Model A B D E K H L Q Z 'N' NPT PORT WeightLPC-10X-100Y-SR01844 240 132 472 50 245 105 140 1721/4"6833.23

Strona 14 - Extensive maintenance

Dimensions mm (in) - Kg (lbs)Model A B D E K H L Q Z'N' NPT PORT'P' NPT PORTWeightLPC-05X-080Y-DA568 178 100 290 38 175 69 120 140

Strona 15 - Troubleshooting

19269346382928278132713121122103143032331435Single ActingNumber Description Qty.1 Bolt 22 Cap 23 Scotch Yoke 14 Bush 25 Retaining Ring 26 Screw 27 W

Strona 16

Figure 15: Exploded View201921232217162524192021182336251524111716222618361537Double ActingNumber Description Qty.22 O-Ring 123 End Flange 124 O-Ring

Strona 17 - Decommissioned

flowserve.comTo find your local Flowserve representative or for more information about Flowserve Corporation, visit www.flowserve.com.FCD LFENIM0002-00

Strona 18 - LPCACTUATORS:NOMENCLATURE

1. Using Flowserve Valves, Actuators and Accessories Correctly1.1 General UsageThe following instructions are designed to assist in unpacking, instal

Strona 19

1.3 Protective ClothingFlowserve products are often used in problematic applications (e.g. extremely high pressures, dangerous, toxic or corrosive me

Strona 20 - Dimensions mm (in) - Kg (lbs)

1.8 StorageIn many cases Flowserve products are manufactured from stainless steel. Products not manufactured from stainless steel are typically provid

Strona 21

1.9 Valve and Actuator VariationsThese instructions cannot claim to cover all details of all possible product variations, nor can they provide inform

Strona 22 - Number Description Qty

2 Installation InstructionsThe LPC range of Limitorque Pneumatic Actuators is a robust, lightweight modular scotch yoke design, available in both spri

Strona 23

2.2 Connection With Valve and Mounting KitThe LPC actuator is usually supplied with the spool piece already assembled. To assemble the actuator onto

Strona 24

2.5 Initial OperationBefore initial operation of the actuator, perform the following checks: • Check that all electrical supply, control and signal

Komentarze do niniejszej Instrukcji