Flowserve 132000 Series Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Flowserve 132000 Series. Flowserve 132000 Series User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 12
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
1
Flow Control Division
Kammer Control Valves
Valves for corrosive applications
Series 132000
Index
1 Using Flowserve valves and actuators correctly
2 Transport and storage
3 Installation
4 Intended use
5 Installation
6 Pressure test pipe section
7 Normal operation and maintenance
8 Trouble-shooting
9 Product description
10 Bonnet
11 Plug and seat
12 Bellows seal
13 Stem
14 Packing
15 Test connection
16 Quick check
17 Masintenance
18 Remove actuator from valve
19 Instal actuator on valve
20 Disassemble valve
21 Assemble valve
22 Trouble-shooting chart
KMEIM3202-01 -02.04
1 USING KÄMMER VALVES AND ACTUATORS
CORRECTLY
1.1 Use
FLOWSERVE control valves and actuators are intended
exclusively for control of mediums in an approved
pressure and temperature range after installation in a
piping system and connection of the actuator to the
control system.
The permissible pressure and temperature limits are
defined in the operating instructions for the individual
valve series.
1.2 Terms concerning safety
The safety terms DANGER, WARNING, CAUTION and
NOTE are used in these instructions to highlight
particular dangers and/or to provide additional
information on aspects that may not be readily
apparent.
DANGER:
indicates that death, severe personal injury
and/or substantial property damage will occur if proper
precautions are not taken.
WARNING:
indicates that death, severe personal injury
and/or substantial property damage can occur if proper
precautions are not taken.
CAUTION:
indicates that minor personal injury and/or
property damage can occur if proper precautions are
not taken.
NOTE:
indicates and provides additional technical
information, which may not be very obvious even to
qualified personnel. Compliance with other, not
particularly emphasised notes, with regard to
transport, assembly, operation and maintenance and
with regard to technical documentation (e.g. in the
operating instruction, product documentation or on
the product itself) is essential, in order to avoid faults,
which in themselves might directly or indirectly cause
severe personal injury or property damage.
1.3 Safety Notes for Operator
The manufacturer is not responsible for the following
and it is therefore necessary to ensure the following
when using FLOWSERVE control valves:
1.3.1 Use valve as intended (Section 1)
DANGER:
Never operate a control valve whose
approved pressure/temperature range according to
the applicable documentation for the valve series is
not sufficient for the operating conditions. Moreover,
it must be ensured that the valve is approved for the
operating medium:
STOP!
Przeglądanie stron 0
1 2 3 4 5 6 ... 11 12

Podsumowanie treści

Strona 1 - Series 132000

1Flow Control DivisionKammer Control ValvesValves for corrosive applicationsSeries 132000Index1 Using Flowserve valves and actuators correctly2 Transp

Strona 2

10Flow Control DivisionKammer Control ValvesFig. 2: Individual parts for series 132 000(also see spare parts lists)123456798181716151413121110101 Bell

Strona 3

11Flow Control DivisionKammer Control ValvesDISASSEMBLE AND ASSEMBLE VALVE20 DISASSEMBLE VALVE(see Fig. 2)DANGER: Since toxic or hazardous substances

Strona 4

12Flow Control DivisionKammer Control ValvesFault Possible Cause RemedyStem motion 1. Packing excessively tightened 1. Tighten gland nut (see table 1

Strona 5

2Flow Control DivisionKammer Control ValvesWARNING: Disconnect or loosen the fastners –particularly between bonnet and housing – only afterthe valve h

Strona 6 - Table 3: Kvs / Cv values

3Flow Control DivisionKammer Control ValvesSTOP!STOP!The counterflanges must have smooth sealing surfacesin all cases, e.g. Form C, Form D or Form E a

Strona 7

4Flow Control DivisionKammer Control Valves5 INSTALLATIONWARNING: Plastic liners on the valves requireparticular protection before/during installatio

Strona 8

5Flow Control DivisionKammer Control Valves6 PRESSURE TESTING PIPING SECTIONThe valve has already been pressure-tested by themanufacturer. When pressu

Strona 9

6Flow Control DivisionKammer Control Valves0,011 0,013 3 50 : 1 Hast C276* Hast C276*0,017 0,020 3 50 : 1 Hast C276* Hast C276*0,025 0,029 3 50 : 1 Ha

Strona 10 - Flow Control Division

7Flow Control DivisionKammer Control Valves13 STEMThe valve stem is equipped with a blowout protectionfeature. This ensures that the valve stem cannot

Strona 11

8Flow Control DivisionKammer Control ValvesFig. 1: Typical valve series 132000 with series 2 actuatorBonnet boltO-Ring (body/bonnet)Insert, thread loc

Strona 12 - 22 Trouble-shooting chart

9Flow Control DivisionKammer Control Valves18 REMOVING ACTUATOR FROM VALVE(See Fig. 1)18.1 Shut off air supply.DANGER: ..Ensure that actuator is not u

Komentarze do niniejszej Instrukcji

Brak uwag