Worcester Actuation Systems
MODELS:
10 - For DataFlo Boards Mounted Inside 10-23 75 Actuators.
25 - For DataFlo Boards Mounted Inside 25/30 75 Actuators.
Inputs:
DFP17 - 1K (120A, 240A, 24D) 1000 ohm Input
DFP17 - 13 (120A, 240A, 24D) 135 ohm Input
DFP17 - 1 (120A, 240A, 24D) 1 to 5 milliamp Input
DFP17 - 4 (120A, 240A, 24D) 4 to 20 milliamp Input
DFP17 - 10 (120A, 240A, 24D) 10 to 50 milliamp Input
DFP17 - 5V (120A, 240A, 24D) 0 to 5 VDC Input
DFP17 - XV (120A, 240A, 24D) 0 to 10 VDC Input
Voltages:
120A - 120 VAC Power Circuits
240A - 240 VAC Power Circuits
24D - 24 VDC Power Circuits
FCD WCAIM2037-00
(Part 17522)
DataFlo Digital Electronic Positioner DFP17
Installation, Operation and Maintenance Instructions
Przeglądanie stron 0
1 2 3 4 5 6 ... 31 32

Podsumowanie treści

Strona 1 - Worcester Actuation Systems

Worcester Actuation SystemsMODELS:10 - For DataFlo Boards Mounted Inside 10-23 75 Actuators.25 - For DataFlo Boards Mounted Inside 25/30 75 Actuators.

Strona 2 - TABLE OF CONTENTS

10 DataFlo Digital Electronic Positioner DFP17 Installation, Operation and Maintenance Instructions WCAIM2037NOTE: For all input signal circuit wiring

Strona 3

WCAIM2037 DataFlo Digital Electronic Positioner DFP17 Installation, Operation and Maintenance Instructions 11Flow ControlWorcester Actuation SystemsFi

Strona 4 - 1.0 GENERAL

12 DataFlo Digital Electronic Positioner DFP17 Installation, Operation and Maintenance Instructions WCAIM20374.0 CALIBRATION AND ADJUSTMENT 4.1 DataFl

Strona 5

WCAIM2037 DataFlo Digital Electronic Positioner DFP17 Installation, Operation and Maintenance Instructions 13K. The display will now read a new feedba

Strona 6

14 DataFlo Digital Electronic Positioner DFP17 Installation, Operation and Maintenance Instructions WCAIM20374.2.4 Operating ModesThe four modes of op

Strona 7

WCAIM2037 DataFlo Digital Electronic Positioner DFP17 Installation, Operation and Maintenance Instructions 15B. Security Code Screen for microchip U5

Strona 8 - AND SERIES 75 ELECTRIC

16 DataFlo Digital Electronic Positioner DFP17 Installation, Operation and Maintenance Instructions WCAIM2037The actuator will run to the setpoint at

Strona 9

WCAIM2037 DataFlo Digital Electronic Positioner DFP17 Installation, Operation and Maintenance Instructions 174.3.14 Electronic Positioner Rotation Lim

Strona 10

18 DataFlo Digital Electronic Positioner DFP17 Installation, Operation and Maintenance Instructions WCAIM2037NOTE: For wiring of alarm outputs refer t

Strona 11

WCAIM2037 DataFlo Digital Electronic Positioner DFP17 Installation, Operation and Maintenance Instructions 195. The display will alternate between SEt

Strona 12

2 DataFlo Digital Electronic Positioner DFP17 Installation, Operation and Maintenance Instructions WCAIM2037Flow ControlWorcester Actuation SystemsTAB

Strona 13

20 DataFlo Digital Electronic Positioner DFP17 Installation, Operation and Maintenance Instructions WCAIM20374. Full CCW position feedback reading: Us

Strona 14

WCAIM2037 DataFlo Digital Electronic Positioner DFP17 Installation, Operation and Maintenance Instructions 214.6.7 Changing Operating ModesIn the Run

Strona 15

22 DataFlo Digital Electronic Positioner DFP17 Installation, Operation and Maintenance Instructions WCAIM2037The 21-point FrE3 and FrE4 curves are set

Strona 16

WCAIM2037 DataFlo Digital Electronic Positioner DFP17 Installation, Operation and Maintenance Instructions 234.9.1 Packet Communications SoftwareSee t

Strona 17

24 DataFlo Digital Electronic Positioner DFP17 Installation, Operation and Maintenance Instructions WCAIM2037NOTE: If you are not using the RS-485 con

Strona 18

WCAIM2037 DataFlo Digital Electronic Positioner DFP17 Installation, Operation and Maintenance Instructions 25Figure 9The following screen appears when

Strona 19

26 DataFlo Digital Electronic Positioner DFP17 Installation, Operation and Maintenance Instructions WCAIM20375.0 TECHNICAL DATA5.1 Allowable Supply Vo

Strona 20

WCAIM2037 DataFlo Digital Electronic Positioner DFP17 Installation, Operation and Maintenance Instructions 276.0 APPLICATION NOTES6.1 Bypass Switch fo

Strona 21

28 DataFlo Digital Electronic Positioner DFP17 Installation, Operation and Maintenance Instructions WCAIM20377.0 TROUBLESHOOTING7.1 GeneralThe followi

Strona 22

Figure 11Test Unit for Milliamp Input Positioner—Set R1 all the way toward the plus end. Adjust R2 for a 20 mA reading.Varying R1 will now provide inp

Strona 23

WCAIM2037 DataFlo Digital Electronic Positioner DFP17 Installation, Operation and Maintenance Instructions 3Flow ControlWorcester Actuation Systems4.3

Strona 24 - Sample RS-485 Connection

30 DataFlo Digital Electronic Positioner DFP17 Installation, Operation and Maintenance Instructions WCAIM20377.3 Troubleshooting GuidelinesUse the fol

Strona 25

WCAIM2037 DataFlo Digital Electronic Positioner DFP17 Installation, Operation and Maintenance Instructions 31Flow ControlWorcester Actuation SystemsCH

Strona 26 - 5.0 TECHNICAL DATA

Flow ControlWorcester Actuation SystemsFlowserve Corporation has established industry leadership in the design and manufacture of its products. When p

Strona 27 - 6.0 APPLICATION NOTES

4 DataFlo Digital Electronic Positioner DFP17 Installation, Operation and Maintenance Instructions WCAIM2037Flow ControlWorcester Actuation Systems1.0

Strona 28 - 7.0 TROUBLESHOOTING

WCAIM2037 DataFlo Digital Electronic Positioner DFP17 Installation, Operation and Maintenance Instructions 5Flow ControlWorcester Actuation Systems1.2

Strona 29

6 DataFlo Digital Electronic Positioner DFP17 Installation, Operation and Maintenance Instructions WCAIM2037Figure 2 – Digital Electronic Positioner C

Strona 30

WCAIM2037 DataFlo Digital Electronic Positioner DFP17 Installation, Operation and Maintenance Instructions 7Figure 2 – Digital Electronic Positioner C

Strona 31

8 DataFlo Digital Electronic Positioner DFP17 Installation, Operation and Maintenance Instructions WCAIM20372.0 DataFlo ELECTRONIC POSITIONERCIRCUIT

Strona 32

WCAIM2037 DataFlo Digital Electronic Positioner DFP17 Installation, Operation and Maintenance Instructions 93.2 Input Signal ConnectionsNOTE: The Digi