Installation InstructionsCircpac HPExperience In MotionSegmented Circumferential Gas Seal for Gas Compressors
21 Precautions 1.1 Please read these instructions carefully. Installation in accordance with the following instructions will contribute to l
3 2.5.3 Minimum runout between the shaft and equipment housing. 2.5.4 Prevention of product sedimentation on the housing, shaft or
3.11 Seal chamber squareness to the shaft center line should be within 0.013 mm per 25.4 mm (0.0005 inch per 1 inch) shaft diameter. Note:
4.10 Disengage setting plates and store separately. 4.11 Inspect equipment and driver alignment in accordance with coupling and/or equipme
5.3 Sizepipingsystemforrequiredowrates.Minimizerestrictionsand determine total pressure drop(s) through piping system to ensure
7 Off-SitePerformanceTesting 7.1 Equipment manufacturers will often execute performance tests with theCircpacHPinstalledonneworretr