USER INSTRUCTIONS
Installation
Operation
Maintenance
Anchor/Darling Double-Disc Gate Valves
2
1
/
2
and over with T-head stem
FCD ADENIM0003-01 - 07/14
Przeglądanie stron 0
1 2 3 4 5 6 ... 27 28

Podsumowanie treści

Strona 1 - USER INSTRUCTIONS

Experience In MotionUSER INSTRUCTIONSInstallationOperationMaintenanceAnchor/Darling Double-Disc Gate Valves 2 1/2 and over with T-head stemFCD ADENIM0

Strona 2 - Contents

Anchor/Darling Double Disc Type Gate Valves FCD ADENIM0003-01 - 07/1410set of packing. There are holes drilled in the top of the lantern ring to acc

Strona 3

11Anchor/Darling Double Disc Type Gate Valves FCD ADENIM0003-01 - 07/14flowserve.comTable 1 Recommended packing gland bolting torques (ft-lb) - dd gat

Strona 4 - 1.0 Valve Description

Anchor/Darling Double Disc Type Gate Valves FCD ADENIM0003-01 - 07/1412600 PRESSURE CLASSValve Size Gland Bolt Size Stem Diameter Packing Size Bo

Strona 5

13Anchor/Darling Double Disc Type Gate Valves FCD ADENIM0003-01 - 07/14flowserve.com1500 PRESSURE CLASSValve Size Gland Bolt Size Stem Diameter Pac

Strona 6 - Figure 5

Anchor/Darling Double Disc Type Gate Valves FCD ADENIM0003-01 - 07/1414Table 2 Body - Bonnet Bolting Torque (ft-lb) Nominal / MaximumSTUD SIZE A193 B

Strona 7 - Installation

15Anchor/Darling Double Disc Type Gate Valves FCD ADENIM0003-01 - 07/14flowserve.comTable 4 Nominal Torque for Non-Pressure Bolting, Including Capscre

Strona 8 - 4.0 Operating The Valve

Anchor/Darling Double Disc Type Gate Valves FCD ADENIM0003-01 - 07/14165.6 Refinishing sealing surfacesMinor discontinuities in both the disc and seat

Strona 9 - 5.0 VALVE MAINTENANCE

17Anchor/Darling Double Disc Type Gate Valves FCD ADENIM0003-01 - 07/14flowserve.comFIGURE 10

Strona 10 - 5.5 Bolting torque values

Anchor/Darling Double Disc Type Gate Valves FCD ADENIM0003-01 - 07/14186.1.1 Handwheels: On handwheel actuated valves (Fig. 10) the handwheel can be

Strona 11 - flowserve.com

19Anchor/Darling Double Disc Type Gate Valves FCD ADENIM0003-01 - 07/14flowserve.comFigure 13

Strona 12

Anchor/Darling Double Disc Type Gate Valves FCD ADENIM0003-01 - 07/142Contents1.0 Valve Description 41.1 Recommended Uses 41.2 Principles Of Operat

Strona 13

Anchor/Darling Double Disc Type Gate Valves FCD ADENIM0003-01 - 07/14206.3 Bonnet Removal – Pressure Seal Joint6.3.1 Unbolt the yoke clamp boltin

Strona 14

21Anchor/Darling Double Disc Type Gate Valves FCD ADENIM0003-01 - 07/14flowserve.comFigure 16

Strona 15

Anchor/Darling Double Disc Type Gate Valves FCD ADENIM0003-01 - 07/1422 withdrawn squarely from the body neck bore. The slightest cocking of the bo

Strona 16 - 6.0 Disassembly

23Anchor/Darling Double Disc Type Gate Valves FCD ADENIM0003-01 - 07/14flowserve.com6.4 Disc Pack & Stem Assembly (Figs. 18 & 19)a) The di

Strona 17

Anchor/Darling Double Disc Type Gate Valves FCD ADENIM0003-01 - 07/1424conditions, Flowserve recommends that parts be re-hardfaced or replaced when t

Strona 18 - 6.1.2 Gear Actuators

25Anchor/Darling Double Disc Type Gate Valves FCD ADENIM0003-01 - 07/14flowserve.comshould be evaluated for cause and corrective measures. Contact Fl

Strona 19

Anchor/Darling Double Disc Type Gate Valves FCD ADENIM0003-01 - 07/14268.1.2 The lower wedge and wedge spring can now be positioned on the upper wed

Strona 20 - Pressure Seal Joint

27Anchor/Darling Double Disc Type Gate Valves FCD ADENIM0003-01 - 07/14flowserve.com By turning each capscrew a couple of turns, proceeding to the ad

Strona 21

flowserve.comTo find your local Flowserve representative or for more information about Flowserve Corporation, visit www.flowserve.com.FCD ADENIM0003-01

Strona 22

3Anchor/Darling Double Disc Type Gate Valves FCD ADENIM0003-01 - 07/14flowserve.com6.0 Disassembly 166.1 Actuators 166.1.1 Handwheel 186.1.2 Gear

Strona 23 - 7.0 INSPECTION AND

Anchor/Darling Double Disc Type Gate Valves FCD ADENIM0003-01 - 07/1441.0 Valve Description1.1 Recommended usesAnchor/Darling Double Disc gate valve

Strona 24 - 7.4 Body

5Anchor/Darling Double Disc Type Gate Valves FCD ADENIM0003-01 - 07/14flowserve.comand high sealing pressure. The greater the valve pressure the tigh

Strona 25 - 8.0 Assembly

Anchor/Darling Double Disc Type Gate Valves FCD ADENIM0003-01 - 07/146Figure 8Figure 7Figure 6Figure 5

Strona 26 - 8.2 Bonnet – flanged joint

7Anchor/Darling Double Disc Type Gate Valves FCD ADENIM0003-01 - 07/14flowserve.comthe acme stem threads. The pneumatic and hydraulic cylinder actuat

Strona 27 - 8.4 Actuators

Anchor/Darling Double Disc Type Gate Valves FCD ADENIM0003-01 - 07/1483.3.4 It is recommended that the valve be installed with the stem vertical, wh

Strona 28

9Anchor/Darling Double Disc Type Gate Valves FCD ADENIM0003-01 - 07/14flowserve.com• Use unauthorized actuator assists such as – pipe wrenches – chea

Komentarze do niniejszej Instrukcji