Installation
Instructions
Experience In Motion
Durametallic
®
Double CRO
Dual single coil spring friction
drive for applications with
water lubrication properties
Przeglądanie stron 0
1 2 3 4 5 6 7 8

Podsumowanie treści

Strona 1 - Instructions

Installation InstructionsExperience In MotionDurametallic® Double CRODual single coil spring friction drive for applications with water lubrication pr

Strona 2 - 1 Equipment Check

1 Equipment Check2Seal Chamber Requirements Figure 11.5 Check assembly drawing included with the Double CRO seal for specic seal desig

Strona 3

31.7 Check gland pilot and bolt holes to ensure they are adaptable to the equipment and are the same as shown on the assembly drawing.1.8 Handle

Strona 4 - Pumps (2 seal chambers)

2.5 Lubricate the other stationary face seat gasket O-ring with water or soap solution and place this O-ring on the back shoulder of the remaining

Strona 5

3.3 Install the rotating seal parts on the shaft or sleeve one piece at a time: • Inner rotating face with rotating face gasket O-ring. •

Strona 6 - Figure 2

64 Operational Recommendations4.1 Do not start up the equipment dry. Vent air from the casing of the pump and the seal chamber before startup.

Strona 7 - 5 Repairs

75 RepairsThis product is a precision sealing device. The design and dimension tolerances are critical to seal performance. Only parts supplied by Flo

Strona 8 - TO REORDER REFER TO

TO REORDER REFER TOB/M #F.O.FIS133eng 10/13 Printed in USAflowserve.comTo find your local Flowserve representativeand find out more about Flowserve Corpo