Strona 2 - Operation Manual

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05102 System Components2.1 Introduction This section gives an overview of the components

Strona 3 - Contents

11Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05flowserve.comThe MX features include: Non-intrusive setup •Separately sealed terminal c

Strona 4

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05122.2.3 Hardware interfaceThe DeviceNet Limitorque Interface is comprised of a minimum o

Strona 5 - ODVA Certification

13Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05flowserve.comTable 2.3 – Total cable length between repeaters or nodes:Network Size 125

Strona 6 - Abbreviations

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/0514NOTE: Recommended DeviceNet cable is Belden 3084A or equal. 121 ohm, ¼ W +/-1% terminat

Strona 7 - 1 Introduction

15Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05flowserve.com3.2 Installation Verification 3.2.1 Network Cabling Installation Verificati

Strona 8 - 1.4 User Knowledge

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05164 Object Model DiagramFigure 4.1 – Object Model of DeviceNet Limitorque Interface4.1

Strona 9

17Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05flowserve.comAn output is a signal produced at the PLC and sent to the actuator via the

Strona 10 - 2 System Components

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/0518Table 4.4 – Output Assembly Instance 102 Assembly Object Instance ID Data Component Nam

Strona 11 - 2.2.2 DeviceNet Field Unit

19Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05flowserve.comTable 4.7 – Input Assembly Instance 105 Assembly Object Instance ID Data Co

Strona 12 - 2.2.4 Network Cable

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/052Limitorque MX DeviceNet Field Unit Installation and Operation Manual©2005 Copyright Flow

Strona 13 - 3.1.1 Site Preparation

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/0520Table 4.9 – Input Assembly Instance 107Assembly Object Instance ID Data Component Name

Strona 14

21Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05flowserve.com4.2.1 DI_Position_and_Bus_Mode_Chan Table 4.12Value Definition0x21 Remote +

Strona 15

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/0522Table 4.16 – Possible values of DI_Actuator_Faults_1_ChanValue Definition0x01 Monitor Re

Strona 16 - 4 Object Model Diagram

23Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05flowserve.comTable 4.20 – Possible values of DI_Actuator_Alarms_ChanValue Definition0x01

Strona 17

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/0524Table 4.25DO_ESD_ Poll_Cnxn Attribute 21Ctrl_Status_ChanAttribute 20Bit 2DO_ESD_ Bit_St

Strona 18 - Table 4.6

25Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05flowserve.com4.2.14 DI_Actuator_Faults_3_ChanTable 4.30Bit 7 – Bit 4 Bit 3 Bit 2 Bit 1

Strona 19

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/0526Table 4.31 – ContinuedAttribute ID Access Rule Name Data Type Description of Attribut

Strona 20

27Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05flowserve.comTable 4.32 – ContinuedAttribute ID Access Rule Name Data Type Descripti

Strona 21 - 4.2.2 DI_Position_Chan

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/0528Table 4.32 – ContinuedAttribute ID Access Rule Name Data Type Description Semantic

Strona 22 - Table 4.19

29Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05flowserve.comTable 4.34Bit 15 - 11 Bit 10 - 9 Bit 3 Unused Scaling 0 = 0 – 100 1 = 0

Strona 23 - 4.2.8 DO_Position_Chan

3Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05flowserve.comContentsDeclaration of DeviceNet Conformance – ODVA Certification 5Abbreviat

Strona 24 - 4.2.13 DI_Alarms_2_Chan

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/0530International Product Name (Attribute ID 13)•Semaphore (Attribute ID 14) •are not sup

Strona 25 - 4.3 Channel Interface Object

31Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05flowserve.comFailedTests DeviceNet Limitorque Interface One or more of the following err

Strona 26 - 4.4 Transducer Block Object

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/0532NOTE 1: At boot time of the DeviceNet Limitorque Interface the values stored in non-vol

Strona 27

33Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05flowserve.com4.4.5 Discrete Output Point Object – Class ID 9 (09hex)The Discrete Output

Strona 28 - 0 = 0 mA 1

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/0534Table 4.41 – Analog Output Point ObjectInstance ID Channel Interface Object Source1 Ins

Strona 29

35Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05flowserve.comThe Device Heartbeat Message is triggered by the Identity Object Instance A

Strona 30 - 4.4.2 Behavior

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05364.6.2 View Settings Refer to Bulletin LMENIM2306, MX Installation and Operation Manual

Strona 31

37Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05flowserve.comThe device has not completed the self test yet.•The device may not be powe

Strona 32

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05385.2 EDS FileThe DeviceNet Limitorque Interface can be configured using Rockwell Automat

Strona 33

39Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05flowserve.com8. Remote control is not selected if not in use. Properly wired if selecte

Strona 34 - 4.5 Network Management

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/0544.5.1 Device Shutdown Message 324.6 Configuration Confirmation 324.6.1 Checking Conn

Strona 35 - 4.6.1 Checking Connections

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/0540Always place the component or board into an anti-static protective bag for transportati

Strona 36 - 5 View DeviceNet Status

41Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05flowserve.com10 Wiring DiagramFigure 10.1 – Typical MX DeviceNet wiring diagram (18-49

Strona 37

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/0542

Strona 38 - 7 Troubleshooting

43Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05flowserve.com

Strona 39 - 7.1 Workmanship

flowserve.comFlowserve Corporation has established industry leadership in the design and manufacture of its products. When properly selected, this Flow

Strona 40 - 9 Regulatory Information

5Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05flowserve.comDeclaration of DeviceNet Conformance – ODVA Certification Declaration of C

Strona 41 - 10 Wiring Diagram

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/056AbbreviationsCIP Common Industrial ProtocolCAN Controller Area NetworkCOS Change of S

Strona 42

7Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05flowserve.com1 Introduction 1.1 Purpose This manual explains how to install and operate

Strona 43

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/058CAUTION: a Directs the user’s attention to general precautions that, if not followed, c

Strona 44

9Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05flowserve.comTable 1.1 – Network specificationsNetwork Size Up to 63 NodesNetwork Length S

Komentarze do niniejszej Instrukcji

Brak uwag