GESTRA Steam Systems
NRGS 11-2
NRGS 16-2
Installation Instructions 810366-01
Level Electrode Types
NRGS 11-2, NRGS 16-2
Przeglądanie stron 0
1 2 3 4 5 6 ... 19 20

Podsumowanie treści

Strona 1 - NRGS 16-2

1GESTRA Steam Systems NRGS 11-2NRGS 16-2Installation Instructions 810366-01Level Electrode Types NRGS 11-2, NRGS 16-2

Strona 2 - Contents

10Functional Elements NRGS 11-2, NRGS 16-2GESTRA Steam SystemsGESTRANRGS 16-2KN1 2 3 456 7 8 9 10 11 1314121 2 34ON6Fig. 5Fig. 4E F G1234HNMJLK65IO65

Strona 3 - Contents continued

11 1 LED „Low-level alarm“ 2 LED “Low-level alarm” 3 LED “Pump ON” 4 Code switch “Measuring range” 5 Button “TEST” 6 Button “RESET” A Thermal i

Strona 4 - Explanatory Notes

12Attention The seating surfaces of the threads or flange provided on the vessel or boiler standpipe must be accurately machined. Fig. 3 Do not

Strona 5 - Technical Data

13Installation continued20≥ 10 DN 50 1" BSP∅ 20∅ 20≤ 90°Fig. 6 Fig. 720∅ 20≥ 10 DN 50 1" BSP≤ 90°∅ 20≤ 1500DN 20DN 20ME≤ 20 1" BSPD

Strona 6 - Technical Data continued

14Key1 Flange PN 40, DN 50 (2"), DIN 2527 Flange PN 40, DN 100 (4"), DIN 25272 For the approval of the boiler standpipe with connecting fl

Strona 7 - GB Reg. Design 2 053 113

15WiringNRGS 11-2, NRGS 16-2 Fuse supply cables with T 2.5 A.ToolsAttention Screwdriver for cross head (“Phillips”) screws, size 1 Screwdriver for

Strona 8

16The measuring range can be switch selected between ≥ 0.5 µS/cm und ≥ 10 µS/cm by means of the code switch 4:1. Unscrew screws E at the electrode t

Strona 9 - Design

171. Switch on mains supply and check the correct functioning of the equipment at the corresponding switchpoints. LEDs 1, 2, 3 are provided for

Strona 10 - NRGS 11-2, NRGS 16-2

18TroubleshootingFault finding listLevel has exceeded switchpoint “High Water” – no functionFault: Mains voltage has not been applied.Remedy: Apply m

Strona 11

19Declaration of conformity Dipl.-Ing. Uwe Bledschun Head of the Design Dept.AnnexWe hereby declare that the equipment NRGS 11-2 and NRGS 16-2 conform

Strona 12 - Installation

2ContentsUsage for the intended purpose ...

Strona 13 - Fig. 6 Fig. 7

20810366-01/406cm · © 2004 GESTRA AG · Bremen · Printed in GermanyGreat BritainFlowserve Flow Control (UK) Ltd.Burrel Road, Haywards HeathWest Sussex

Strona 14

3WiringNRGS 11-2, NRGS 16-2 ...15

Strona 15 - 0.5 µS/cm

4Important NotesDangerWhen loosening the electrode steam or hot water might escape. This presents the danger of severe scalds to the whole body.It is

Strona 16 - ≥ 10 µS/cm

5Explanatory Notes continuedSystem descriptionThe compact system NRGS 11-2, NRGS 16-2 works according to the conductivity measurement prin-ciple. Wit

Strona 17 - Operation

6NRGS 11-2, NRGS 16-2 continuedTechnical Data continuedLengths supplied 500 mm 1000 mm 1500 mmMains supply 230 V +/– 10 %, 50/60 Hz 115 V +/– 10 %

Strona 18 - Troubleshooting

7Corrosion resistanceProvided that the equipment is used for its intended purpose, its safety is not impaired by corrosion.SizingThe body must not be

Strona 19 - Head of the Design Dept

8DimensionsTechnical Data continuedFig. 1173140337.5∅ 42 1", EN ISO 228-1500, 1000, 1500

Strona 20 - GESTRA AG

9Design NRGS 11-2, NRGS 16-2Fig. 2Fig. 3N 8N 100.5∅ 40 1", DIN 228ACBD5065-70≥ 14