LNN, LNNV, LNNC USER INSTRUCTIONS ENGLISH 71569074 06-14
Page 12 of 56 flowserve.com
3.3.5 Bearing housing
Two grease nipples enable grease lubricated
bearings to be replenished between major service
intervals. For oil lubricated bearings, a constant level
oiler is fitted.
3.3.6 Stuffing box housing
The stuffing box housing has a spigot (rabbet) fit
between the pump casing and bearing housing for
optimum concentricity. The design enables a
number of sealing options to be fitted.
3.3.7 Shaft seal
The mechanical seal(s) attached to the pump shaft
seals the pumped liquid from the environment.
Gland packing may be fitted as an option.
3.3.8 Driver
The driver is normally an electric motor. Different drive
configurations may be fitted such as internal
combustion engines, turbines, hydraulic motors etc
driving via couplings, belts, gearboxes, drive shafts etc.
3.3.9 Accessories
Accessories may be fitted when specified by the
customer.
3.4 Performance and operating limits
This product has been selected to meet the
specifications of your purchase order. See section 1.5.
The following data is included as additional information to
help with your installation. It is typical, and factors such
as temperature, materials, and seal type may influence
this data. If required, a definitive statement for your
particular application can be obtained from Flowserve.
3.4.1 Operating limits
Pumped liquid temperature limits
-20 to +80 ºC
(-4 to +176 ºF)
High temperature liquid limits *
-20 to +130 ºC
(-4 to +266 ºF)
Maximum ambient temperature
-20 to +40 ºC
(-4 to +104 ºF)
Maximum soft solids in suspension *
up to 3 % by volume
(refer for size limits)
* Subject to written agreement from Flowserve.
3.4.2 Pump and impeller data
Impeller
minimum
passage size
mm (in.)
Nominal
wear ring
diameter
mm (in.)
Mean radial
wear ring
clearance
mm (in.)
Clearances for non-metallic wear rings are smaller,
typically 50 to 65% of those for the standard metallic rings shown
above.