5
Set Dispensing Rate Figure 2
30 - 32
14 - 15
7 - 8
4 - 5
3 - 4
2.5 - 3
2 - 2.5
1 - 2
1 - 1.4
0.8 - 1
0.7 - 0.8
0.5 - 0.7
0.25 - 0.3
0.1 - 0.15
475cc Jumbo Luber
Setting to Empty
125cc Mini Luber
Setting to Empty
Dispensing
Rate
*cc per day
14 days
1 month
2 months
3 months
4 months
4.5 months
6 months
12 months
24 months
123612 B
123612 B
123612 B
123612 B
123612 B
123612 B
123612 B
123612 B
123612 B
123612 B
123612 B
123612 B
14 days
1 month
2 months
3 months
4 months
4.5 months
6 months
8 months
12 months
24 months
123612 B
123612 B
123612 B
123612 B
123612 B
123612 B
123612 B
Unit Life Switch Setting Unit Life Switch Setting
Not Recommended over 24 months
1 M 2 M 3 M C M 1 2 M B O
N
I
G
H
T
O
N
OFF
2 Normal Operation
2.1 Once the SLD auto-luber unit is switched on, an electro-chemical reaction
cell is activated that creates inert nitrogen gas. This produces an internal
pressure of up to 345 kPa (50 psi) that expands a bladder that acts against
a piston to force the lubricant out of the dispensing cylinder at a controlled
rate according to the specic time period previously selected. This is an
automatic operation.
2.2 After initial activation, there is a delay before enough nitrogen gas is
generated to start moving the piston to dispense lubricant. The longer the
dispensing period selected the longer the delay before lubricant is dispensed.
See Figure 3. If immediate dispensing is desired, prestart the SLD auto-
luber unit 12 hours prior to installation by moving all DIP switches to the “On”
position. After this period of time, return all DIP switches to “Off” and reselect
*Note that one stroke from a typical hand grease gun is approximately
equal to one cubic centimeter (cc) at normal (101 KPa and 20°C, 14.7
psia and 68°F) atmospheric conditions
desired dispensing
period. If this step
is not done and all
switches are left
on, then the entire
contents will be
dispensed in only
14 days.