Flowserve Mechanical and Hydraulic Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Flowserve Mechanical and Hydraulic. Flowserve Mechanical and Hydraulic User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 28
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Experience In Motion
USER INSTRUCTIONS
Installation
Operation
Maintenance
Mechanical and Hydraulic Manual Overrides
FCD LFENIM0004-00-AQ – (05/15)
Przeglądanie stron 0
1 2 3 4 5 6 ... 27 28

Podsumowanie treści

Strona 1 - USER INSTRUCTIONS

Experience In MotionUSER INSTRUCTIONSInstallationOperationMaintenanceMechanical and Hydraulic Manual OverridesFCD LFENIM0004-00-AQ – (05/15)

Strona 2 - Contents

Mechanical and Hydraulic Overrides FCD LFENIM0004-00-AQ – 05/1510Figure 4 – Detail of LPS Double-Acting with Enclosed Jackscrew Override (Declutchabl

Strona 3

11Mechanical and Hydraulic Overrides FCD LFENIM0004-00-AQ – 05/15flowserve.comThe Not Enclosed Jackscrew is a simple manual override solution, consist

Strona 4 - Standard Information

Mechanical and Hydraulic Overrides FCD LFENIM0004-00-AQ – 05/15122.2.2 Operation – Not Enclosed Jackscrew Override Installed on LPS/LPC Single-Acti

Strona 5 - 1.4 Qualified Personnel

13Mechanical and Hydraulic Overrides FCD LFENIM0004-00-AQ – 05/15flowserve.com2.2.2.2 Restoring Automatic Operation To restore automatic operation:2.2

Strona 6 - 1.10 Unpacking

Mechanical and Hydraulic Overrides FCD LFENIM0004-00-AQ – 05/15142.2.3.2 Restoring Automatic Operation To restore automatic operation:2.2.3.2.1 Oper

Strona 7 - Mechanical Manual Overrides

15Mechanical and Hydraulic Overrides FCD LFENIM0004-00-AQ – 05/15flowserve.com2.3.1.3 Tighten the seal nut.2.3.1.4 Pneumatically stroke the actuat

Strona 8

Mechanical and Hydraulic Overrides FCD LFENIM0004-00-AQ – 05/15163 Hydraulic Manual Overrides Hydraulic Manual Overrides of LFPS heavy duty actuators

Strona 9

17Mechanical and Hydraulic Overrides FCD LFENIM0004-00-AQ – 05/15flowserve.com3.1.1 Installation - Travel-Stop Bolts Adjustment Hydraulic Hand Pump Ov

Strona 10

Mechanical and Hydraulic Overrides FCD LFENIM0004-00-AQ – 05/15183.1.2.1.3 If an additional stop valve SV2 is installed, make sure it is in the open

Strona 11 - flowserve.com

19Mechanical and Hydraulic Overrides FCD LFENIM0004-00-AQ – 05/15flowserve.comFigure 13 – Details of Hydraulic Hand Pump Manual Override for Single-Ac

Strona 12

Mechanical and Hydraulic Overrides FCD LFENIM0004-00-AQ – 05/152Contents1 Standard Information 41.1 Using Flowserve Valves, Actuators & Accessor

Strona 13

Mechanical and Hydraulic Overrides FCD LFENIM0004-00-AQ – 05/15203.1.3.1.5 To stroke the actuator in the open direction, switch the manual selector

Strona 14 - LPS Single Acting Actuators

21Mechanical and Hydraulic Overrides FCD LFENIM0004-00-AQ – 05/15flowserve.com3.1.4. Operation – Hydraulic Hand Pump Override Installed on LHS Single

Strona 15

Mechanical and Hydraulic Overrides FCD LFENIM0004-00-AQ – 05/1522Figure 18 – Hydraulic Diagram of Manual Override for LHS Single Acting3.1.4.2 Restor

Strona 16 - Hydraulic Manual Overrides

23Mechanical and Hydraulic Overrides FCD LFENIM0004-00-AQ – 05/15flowserve.com3.1.5.1 Manual Operationa CAUTION: prior to operating the actuator by m

Strona 17

Mechanical and Hydraulic Overrides FCD LFENIM0004-00-AQ – 05/15244 Maintenance InstructionsMechanical and hydraulic manual overrides of LFPS heavy du

Strona 18

25Mechanical and Hydraulic Overrides FCD LFENIM0004-00-AQ – 05/15flowserve.com4.1 Service KitsSpare Parts of both Mechanical and Hydraulic Manual Ove

Strona 19

Mechanical and Hydraulic Overrides FCD LFENIM0004-00-AQ – 05/1526Table 3 – Spare Parts of Not Enclosed Jack Screw Manual OverrideNUMBER DESCRIPTION Q

Strona 20

27Mechanical and Hydraulic Overrides FCD LFENIM0004-00-AQ – 05/15flowserve.comTable 5 – Spare Parts of Hydraulic Manual Override: Hydraulic Cylinder A

Strona 21

flowserve.comTo find your local Flowserve representative or for more information about Flowserve Corporation, visit www.flowserve.com.FCD LFENIM0004-00

Strona 22

3Mechanical and Hydraulic Overrides FCD LFENIM0004-00-AQ – 05/15flowserve.comFiguresFigure 1 – Enclosed Jackscrew Manual Override for Double-Acting

Strona 23

Mechanical and Hydraulic Overrides FCD LFENIM0004-00-AQ – 05/1541 Standard Information1.1 Using Flowserve Valves, Actuators and Accessories Correct

Strona 24 - Maintenance Instructions

5Mechanical and Hydraulic Overrides FCD LFENIM0004-00-AQ – 05/15flowserve.com1.4 Qualified PersonnelOnly Qualified Personnel should perform installati

Strona 25 - 4.1 Service Kits

Mechanical and Hydraulic Overrides FCD LFENIM0004-00-AQ – 05/1561.8 StorageIn many cases Flowserve products are manufactured from stainless steel.

Strona 26

7Mechanical and Hydraulic Overrides FCD LFENIM0004-00-AQ – 05/15flowserve.com2 Mechanical Manual OverridesMechanical Manual Overrides on LFPS heavy du

Strona 27

Mechanical and Hydraulic Overrides FCD LFENIM0004-00-AQ – 05/1582.1.1 Installation - Travel-Stop Bolts Adjustment Enclosed Jackscrew Override Inst

Strona 28

9Mechanical and Hydraulic Overrides FCD LFENIM0004-00-AQ – 05/15flowserve.com2.1.2.1.3 Operate the handwheel counterclockwise (CCW) to open the valve

Komentarze do niniejszej Instrukcji

Brak uwag