FAULT SYMPTOM
Pump overheats and seizes
Bearings have short life
Pump vibrates or is noisy
Mechanical seal has short life
Mechanical seal leaks excessively
Pump requires excessive power
Pump loses prime after starting
Insufficient pressure developed
Insufficient capacity delivered
Pump does not deliver liquid
PROBABLE CAUSES POSSIBLE REMEDIES
B. Mechanical troubles
l
l
l
l
l
l
Misalignment due to pipe strain. Check the flange connections and eliminate strains
using elastic couplings or a method permitted.
l
Improperly designed foundation. Check setting of baseplate: tighten, adjust, grout
base as required.
l
l
l
l
l
Shaft bent. Check shaft runouts are within acceptable values.
CONSULT FLOWSERVE.
l
l
l
l
Rotating part rubbing on stationary part internally. Check and CONSULT FLOWSERVE, if necessary.
l
l
l
l
l
Bearings worn Replace bearings.
l
l
l
Wearing ring surfaces worn. Replace worn wear ring/surfaces.
l
l
l
Impeller damaged or eroded. Replace or CONSULT FLOWSERVE for improved
material selection.
l
Leakage under sleeve due to joint failure. Replace joint and check for damage.
l
l
Shaft sleeve worn or scored or running off centre. Check and renew defective parts.
l
l
l
Mechanical seal improperly installed. Check alignment of faces or damaged parts and
assembly method used.
l
l
l
Incorrect type of mechanical seal for operating
conditions.
CONSULT FLOWSERVE.
l
l
l
l
l
Shaft running off centre because of worn bearings
or misalignment.
Check misalignment and correct if necessary. If
alignment satisfactory check bearings for excessive
wear.
l
l
l
l
l
Impeller out of balance resulting in vibration.
l
l
l
Abrasive solids in liquid pumped.
l
l
Internal misalignment of parts preventing seal ring
and seat from mating properly.
Check and CONSULT FLOWSERVE.
l
l
Mechanical seal was run dry. Check mechanical seal condition and source of dry
running and repair.
l
l
Internal misalignment due to improper repairs
causing impeller to rub.
Check method of assembly, possible damage or
state of cleanliness during assembly.
Remedy or CONSULT FLOWSERVE, if necessary.
l
l
l
Excessive thrust caused by a mechanical failure
inside the pump.
Check wear condition of impeller, its clearances and
liquid passages.
l
l
Excessive grease in ball bearings. Check method of regreasing.
l
l
Lack of lubrication for bearings. Check hours run since last change of lubricant, the
schedule and its basis.