Flowserve SPECTORcontrol Instrukcja Użytkownika Strona 76

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 88
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 75
76
Burner Menu – continued
Malfunction history
1. In the menu Malfunction History press button .
2. The display field shows the values of the
last malfunction signal.
3. To show further malfunction signals press
button .
4. To go to the fault history press button .
Fault history
1. In the menu Malfunction History press button .
2. The abbreviated malfunction messages in-
dicated by the display enable a quick
search.
3. To show further malfunction messages
press button .
Malfunction
Logo
Code:
Date:
Diag.:
Fuel:
Operating hrs:
Class:
Time:
Efficiency:
Phase:
Start-up no.:
02.03.04
0
09.15.50
0
26 Flame outage
60
100.0%
154502
Gas
Item: 0
Fault History
Logo
Code:
Diag.:
Fuel:
Class:
Efficiency:
Phase:
Start-up no.:
Gas
162
3212
0.0%
87 Feedback AZL
Item: 0
Przeglądanie stron 75