Flowserve APEX A9000 Accord Instrukcja Użytkownika Strona 5

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 42
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 4
5
5.2 Limit switches
Type SPDT
Size Sub Sub miniature
Rating 3A, 125 VAC / 2A, 30VDC
Mechanical life >1 x 10
6
operations
Namur sensors
Type P+F NJ2 V3 N Inductive DIN 19234
Load current <1mA>3mA
Voltage range 5-25 VDC
Hysteresis 3-15% (5% typical)
Temp range -25° to +100° C (-248° to 373° F)
Namur sensors
Type P+F SJ2-N
Normal Voltage 8 VDC
Load current 1mA<I<3mA
Voltage range (5-25 VDC)
Hysteresis (max) 0.2%
Temp range -25° to +100° C (-248° to 373° F)
Namur sensors
Type P+F SJ2-SN
Normal Voltage 8 VDC
Load current 1mA<I<3mA
Voltage range 5-25 VDC
Hysteresis (max) (0.2%)
Temp range -40° to +100° C (-233° to 373° F)
Namur sensors
Type P+F SJ2-S1N
Normal Voltage 8 VDC
Load current 1mA<I<3mA
Voltage range 5-25 VDC
Hysteresis (max) 0.2%
Temp range -25° to +100° C (-248° to 373° F)
Proximity switches
Type SPDT
Rating 10W
Voltage max 200VDC
Current max 500mA
Contact resistance max 0.2 ohm
Operating time 1.0 ms
Transmitter
Power supply 12-28 VDC
Output 1-22 mA
Resolution 0.1%
Linearity ±0.5%
Load impedance 600 ohm at (12 VDC and 20mA)
Alarm Output
Supply 3-28 VDC
Output 20mA @ 24 VDC
Przeglądanie stron 4