Flowserve ORGS 11-2 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Flowserve ORGS 11-2. Flowserve ORGS 11-2 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 20
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
1
ORGS 11-2
Installation Instructions 810801-00
Oil Detector & Alarm ORGS 11-2
Przeglądanie stron 0
1 2 3 4 5 6 ... 19 20

Podsumowanie treści

Strona 1 - ORGS 11-2

1ORGS 11-2Installation Instructions 810801-00Oil Detector & Alarm ORGS 11-2

Strona 2 - Contents

10Technical Data – continued –InstallationInstallation requirementsPower consumption5 VAFuseThermal fuse Tmax = 102°CSensitivityRange 1: 10 µS/cmRange

Strona 3 - Dimensions

11Installation – continued –Installation requirements – continued –1. Use supporting flanges to install the oil detector ORGS 11-2 in a suitab

Strona 4

12Use multi-core flexible control cable with min. conductor size 1.5 mm² for wiring.1. Undo screws and remove the housing cover , Fig. 32. Uns

Strona 5

13The measuring range can be switch-selected between ≥ 0.5 µS/cm and ≥ 10 µS/cmby means of a code switch :1. Undo screws of the electrode ter

Strona 6

141. LEDs and serve as visual checks for the operating modes, fig. 4. To check thecorrect functioning of the LEDs remove the housing cover. Se

Strona 7 - Important Notes

15AnnexDangerThe terminal strip of the ORGS 11-1 is live during operation.This presents the danger of electric shock.Cut off power supply before remov

Strona 8 - Explanatory Notes

161 Automatically operated rapid-action deaerator2 Return valve (ball valve DN 10 L, PN 500)3 Discharge line DN 124 Standard orifice plate5 Main engin

Strona 9 - – continued –

17Fig. 13Examples of installationFig. 14Cooling watercycleCooling watercycle198762543198726543

Strona 12

2ContentsUsage for the intended purpose ...7Safety note...

Strona 13 - Standard Setting

20810801-00/503cs · © 2003 GESTRA GmbH · Bremen · Printed in GermanyGESTRA GmbHPostfach 10 54 60, D-28054 Bremen, Münchener Str. 77, D-28215 BremenT

Strona 14 - Operation

3DimensionsFig. 14515708.5100303011860100~335~586~730~96250

Strona 15

4DesignFig. 2ABBCDGFE

Strona 16 - Annex – continued –

5Fig. 3Fig. 4DesignHI J21345KLMNO

Strona 17 - Examples of installation

6LED “Oil alarm”LED “Oil alarm”LED (without function)LED (without function)Code switch “Measuring range”Measuring electrode ORGS 11-1Supporting flange

Strona 18

7Important NotesSafety NoteDangerWhen loosening the electrode hot cooling water might escape. Thispresents the danger of severe scalding. It is theref

Strona 19

8Explanatory NotesScope of SupplyFunctionORGS 11-21 Oil detector & alarm ORGS 11-2, PN 62 Sealing plugs for cable entry1 Installation manualDescri

Strona 20 - GESTRA GmbH

9Technical DataOil detector & alarm ORGS 11-2Test approvalORGS 11-2: GL 17106-00 HHAdmissible service pressure6 barg (87 psig)Admissible service t

Komentarze do niniejszej Instrukcji

Brak uwag