5
Classification pursuant to Article 9 of the Pressure Equipment Directive (PED) 97/23/EC
Classification pursuant to Annex 1 of ATEX Directive 94/9/EC
Important Notes continued
Type
PA 46, PA 47 MPA 46, MPA 47
Fluid Gas, steam Liquid Gas, steam Liquid
Fluid group 1 2 1 2 1 2 1 2
Application no yes no yes no yes no yes
Type
PN CLASS
Nominal size DN
Exception pursuant to article 3.3 Category I
MPA 46 CL 150 20, 25, 32, 40, 50
MPA 46 CL 300 20, 25, 32 40, 50
MPA 46 PN 40 20, 25, 32 40, 50
MPA 47 CL 400 25 40, 50
MPA 47 PN 63 25 40, 50
PA 46 CL 150 20, 25, 32, 40, 50
PA 46 CL 300 20, 25, 32 40, 50
PA 46 PN 40 20, 25, 32 40, 50
PA 47 CL 400 25 40, 50
PA 47 PN 63 25 40, 50
CE Marking no
0525
Type
PA 46, PA 47 MPA 46, MPA 47
Equipment group II II
Equipment category 2 2
Potentially explosive atmosphere (1999/92/EC) 1, 2, 21, 22 1, 2, 21, 22
CE Marking / EX Marking
II 2 G/D c X
II 2 G/D c X
Marking “X”
The equipment itself does not generate inadmissibly high
surface temperatures. The user must make sure that the
operating fluid does not generate inadmissibly high surface
temperatures.